Switchboard Photo's For the installation of the Powerwall system, we will need to connect into your switchboard.
Please upload a photo of your switchboard, with the doors open so we can see the circuit breakers.
Please also upload a photo of the switchboard and surrounding area.
Gateway Location Photo The Tesla Gateway is the central part of the Powerwall system. This component allows you to be off grid in an outage, as it isolates the grid from your electrical system.
The Gateway Dimensions are: H=660mm, W=411mm, D=149mm.
The Gateway is best positioned close to the switchboard, although It can be up to 10m away. As the large mains cables are run through it to provide backup power, it is best close. Please can you upload a photograph of a location for the Gateway and surrounding area.
Powerwall Location
Please upload a photo of your preferred location for the Powerwall.
The dimensions of the Powerwall are H=1150mm, W=753mm, D=147mm
Ideally, the Powerwall needs 600mm spacing around it for ventilation on all sides.
If the Powerwall is backing onto a Habitable room(Lounge, Bedroom, Kitchen), then it needs to be installed on a fire proof material. such as Hardie board or concrete. This can be added if the desired wall is a combustable material.
The Powerwall can be installed inside or outside. If you would prefer outside, it needs to be on a wall out of the Sun, generally East or South, or a shaded West wall.
Other Questions
Please feel free to ask any other questions regarding the installation of the Powerwall components. We will do our best to guide you through the best locations and setup for your system.